Bitte benutzen Sie diese Kennung, um auf die Ressource zu verweisen:
https://doi.org/10.48548/pubdata-1418
Ressourcentyp | Zeitschriftenartikel |
Titel | Maximal strength measurement: A critical evaluation of common methods - a narrative review |
DOI | 10.48548/pubdata-1418 |
Handle | 20.500.14123/1487 |
Autor*in | Warneke, Konstantin 0000-0003-4964-2867 Wagner, Carl-Maximilian 0009-0003-7879-1287 Keiner, Michael 0000-0002-1817-1743 Hillebrecht, Martin 139928820 Schiemann, Stephan 0000-0002-0703-8509 131474332 Behm, David George 0000-0002-9406-6056 Wallot, Sebastian 0000-0002-3626-3940 Wirth, Klaus 0000-0001-9862-4951 |
Abstract | Measuring maximal strength (MSt) is a very common performance diagnoses, especially in elite and competitive sports. The most popular procedure in test batteries is to test the one repetition maximum (1RM). Since testing maximum dynamic strength is very time consuming, it often suggested to use isometric testing conditions instead. This suggestion is based on the assumption that the high Pearson correlation coefficients of r ≥ 0.7 between isometric and dynamic conditions indicate that both tests would provide similar measures of MSt. However, calculating r provides information about the relationship between two parameters, but does not provide any statement about the agreement or concordance of two testing procedures. Hence, to assess replaceability, the concordance correlation coefficient (ρc) and the Bland-Altman analysis including the mean absolute error (MAE) and the mean absolute percentage error (MAPE) seem to be more appropriate. Therefore, an exemplary model based on r = 0.55 showed ρc = 0.53, A MAE of 413.58 N and a MAPE = 23.6% with a range of −1,000–800 N within 95% Confidence interval (95%CI), while r = 0.7 and 0.92 showed ρc = 0.68 with a MAE = 304.51N/MAPE = 17.4% with a range of −750 N–600 N within a 95% CI and ρc = 0.9 with a MAE = 139.99/MAPE = 7.1% with a range of −200–450 N within a 95% CI, respectively. This model illustrates the limited validity of correlation coefficients to evaluate the replaceability of two testing procedures. Interpretation and classification of ρc, MAE and MAPE seem to depend on expected changes of the measured parameter. A MAPE of about 17% between two testing procedures can be assumed to be intolerably high. |
Sprache | Englisch |
Schlagwörter | Maximal Strength; Performance; Testing |
Jahr der Veröffentlichung in PubData | 2024 |
Art der Veröffentlichung | Zweitveröffentlichung |
Publikationsversion | Veröffentlichte Version |
Datum der Erstveröffentlichung | 2023-02-17 |
Entstehungskontext | Forschung |
Anmerkungen | This publication was funded by the Open Access Publication Fund of Leuphana University Lüneburg. |
Veröffentlicht durch | Medien- und Informationszentrum, Leuphana Universität Lüneburg |
Zugehörige Ressourcen |
Informationen zur Erstveröffentlichung
Element | Wert |
---|---|
Ressourcentyp | Zeitschrift |
Titel des Ressourcentyps | Frontiers in Sports and Active Living |
Identifier | DOI: 10.3389/fspor.2023.1105201 |
Publikationsjahr | 2023 |
Band | 5 |
Nummer | 1105201 |
Nummerntyp | Artikel |
Verlag / Anbieter | Frontiers |
Dateien zu dieser Ressource:
Datei | Beschreibung | Größe | Format | |
---|---|---|---|---|
Warneke_Maximal_strength_measurement.pdf Lizenz: open-access | 1.08 MB | Adobe PDF | Öffnen/Anzeigen |
Alle Ressourcen in diesem Repository sind urheberrechtlich geschützt, soweit nicht anderweitig angezeigt.
Ansichten
Datensatz Exporte
Zugriffsstatistik
Seitenaufruf(e): 7
Download(s): 7